Rabu, 13 April 2016

Semi Automatic Egg Harvester Machine

Introduce, Rame-Hart Egg Harvester

      A series of single station machines is available from ramé-hart to fill the need for small to medium-size manufacturers of embryonic egg-cultured vaccines.

The semi-automatic egg machines incorporate the inoculating and harvesting components normally used in our fully-automated machines. Only the tray-handling and positioning mechanisms have been eliminated. In this way, although the trays must be loaded manually and the spent eggs manually unloaded, much of the cost of the automatic inoculating/harvesting system has been eliminated while still using the proven inoculating and harvesting methods.

Another advantage of the semi-automatic machines is that they can be easily modified to work with different size egg trays and other special custom requirements.

The semi-automatic machines are also available with the needle sanitizing option on the inoculator and fluid inspection and rejection on the harvester.
Harvester Nozzle
Accumulator

Disassembly and Cleaning

1.Removal of Harvesting Head
       a. Remove Harvest tubes from Harvesr nozzles
       b. Remove the thumbscrewa for each of the nozzle bars and remove each nozzles bar.
       c. Remove the harvest nozzles from the nozzle bar by pulling out the nozzle bayonet clips.                  The nozzle sleeve will fall away from the nozzle.
       d. Open the pinch bar and pull out the harvest tubes. 

2.Removal of Accumulator
       a. Empty the accumulator. Open the valve at the bottom.
       b. Remove the harvest tubes from the barbs at the top of the accumulator.
       c. Remove the vacuum tube from the top of the accumulator.
       d. Remove the top of Accumulator.
       e. Unscrew the tie rods that hold the upper and lower plates to the glass cylinder. 


3. Clean all machine surfaces
The nozzles, the nozzle bars and the accumulator may be autoclaved

Tag # Vaccine, Machine, Egg, Harvest, Chicken, Veterinary, Animal, Cleaning, Nozzle, Maintenance


Selasa, 12 April 2016

ACCES DOOR SYSTEM



HID's EntryProx stand-alone reader truly stands alone in what it delivers. Compatible with all HID proximity cards and keytags, EntryProx™ provides single-door proximity access control and is ideal for unique applications. The reader, designed to be weatherand vandal-resistant, can be mounted indoors or outdoors up to 10 feet away from the control unit using the detachable antenna module. The versatile, attractive unit is easily modified to become an on-line reader by switching to Wiegand output mode, allowing it to connect to any OEM controller and provide card and PIN output.
The ADA-compliant 12-position keypad features large white-on-black numbers, enabling PIN entry or programming, with optional audio feedback and a raised dot on the 5 key. For extra security, EntryProx's keypad incorporates the "invalid PIN" lockout feature, preventing unauthorized trial-and-error PIN code entry.
The reader also features faster programming, enabling end-users to batch load up to 2,000 HID cards or keytags, in any format up to 37 bits, by entering a single keypad command sequence. A Block Delete feature allows for efficient badge administration by deleting a sequential range of cards/keytags from the EntryProx by user location.
To gain access to the controlled door, the user present their card to the reader and / or enters their PIN code into the keypad. The units searches its memory for that card or Pin code. If the unit finds the card PIN Code, it unlocks the door or performs some other action that has been programmed for that user.
Request to Exit Input

When the EntryProx Request to Exit (REX) input receives a momentary switch closure, it engages the main relay for the programmed access time. It can be connected to a wall-mounted exit button, to a push button under a reception desk, or to the relay output of passive infrared motion detector mounted above the door on the secure side.

On My Place the Exit button function to release magnetic lock, and then the door can open. 
Doors are mounted EntryProx must already be installed mechanical door closer. So that the door can be locked again automatically. 


References : hidglobal

Minggu, 10 April 2016

LPG leak Detector

Panel Control and Monitoring

For safety and security needs of homes, cafes, restaurants, hotels, hospitals that use LPG as fuel for cooking. In terms of the resultant danger of leakage of gas, it takes a gas leak detector. Its function also activates the alarm in the form of sound or siren notifiers gas leak.

The requirements made of gas leakage detection system is simple, but the function is the same with a sophisticated gas detectors are already there.

In order for the manufacture of detection devices might function automatically cut off the flow of gas from the source (tube gas / gas pipeline public) also mounted solenoid valve which is controlled by the panel.

The following sections required parts:
1. LPG gas sensor
2. Solenoid Valve (Normally Close)
3. Alarm Panel
4. Cable Connector


gas detectors

Usually installed near the stove and gas storage facilities.
For a number of detectors can be installed as much as possible, adapted to the number of points used gas outlet.

Making the panel detector such that I made this so I suggested. advantages, in addition to easy in its manufacture is also cheap prices.
If there is damage, spare parts can be purchased near your home.
Panel Components:
1. Relay
2. MCB
3. Indicator Light
4. Buzzer
5. Pushbutton
6. Terminal cable

Isn't it Easy and cheap?

If you need and do not want complicated
We are ready to help you.









Jumat, 08 April 2016

Problem : Replacing Bearing & Mechanical Seals Electrolux EWF 1082 G

The plan today will examine the washing machine Electrolux EWF 1082 G are reported damaged. Once in trying to running the machine, his drums sound squealed. The initial conclusion we suspect rotary shaft or bearing problem.



And sure enough, after opening the back cover we find a melt grease in the back of the rotary chamber. yes, this is the cause of sound squealed. just as our previous estimates.


The next step is to open a pulley, but here is our difficulty in opening pulley bolt. 

Perhaps because we are beginners, confused about the direction of rotation to unlock the bolt. Whether clockwise or counterclockwise?

We're stuck here

If among you who know where the direction of rotation?
please help us


tags: #electrolux washing machines, replacing bearing, clothes washing, rotary, , mendecit, macet, mesin cuci, drum berisik, stuck chamber

Semi Automatic Printing & Labelling Machine


I introduced printing and labeling machines that help do the job printing batch number, date of manufacture and expiry date.

The type of packaging used is a 6 ml vial bottle.




The machine is being used

At least two people operating the machine, one person puts the vial vial one more person assigned to conduct checks and recek. Further incorporate visual checks vial which passes into the packaging carton.
Trouble Shooting : 

It could happen problem in running the machine, as is often the case that, she decided label paper. Frequent disconnects due label paper label behind the exposed blade cutting through, of course poor 
paper quality label.

If the good quality label paper, then the machine would smoothly without problems.
Broken Label Recovery